Hydro Power Station Inspection Details

Certified Company ISO 9001-2008
image
  • Client:Eskom South Africa
  • Project Date:August 2019
  • Category:NDT Services
  • Project Manager:Seelan Moodley
  • Status:Completed
  • Tags:Industrial, Phased Array

Hydro Power Station Inspection

Fermion Technologies has developed a special offering for the inspection of Hydro Power Station Inspections.  This offering assists our clients a complete assurance of the integrity of the equipment and safe working practice.

What we did

The Hydro Power Station Inspection consists of the following:


• Rotor Shaft inspection


• Thrust Bearing Inspection

• Penstock Inspection of weld’s


• Turbine floor components

• Bolt ultrasonic inspections


• Electrical Rectification surveys


• Pinion shaft inspection


• Lubrication sampling

  • Rotor Shaft

    NDT: Ultrasonic inspection and Magnetic Particle evaluations
.

    Mechanical inspection: Alignment and bearing inspection.

  • Bearing Inspection


    NDT: Liquid Penetrant and Magnetic particle evaluation as well as ultrasonic evaluation for white metal damage and seperation

  • Penstock Inspection


    NDT: In-situ testing of Penstock internally and external if necessary with means of Magnetic Particle and Ultrasonic evaluations and wall thickness survey

  • Bolt Inspection


    NDT: Magnetic particle or Ultrasonic inspection

  • Oil Analysis

    NDT: Extraction of oil samples from gear boxes and testing for wear and metal content as well as other contamination that affects optimal running of rotating equipment.

  • Electrical Rectification Survey

    Using latest IR camera’s thermal imaging survey is done on electrical equipment and rectification in order to determine hot spots or faults

image